Northern Aquarius Plus Patient Monitor with ECG & Touchscreen
$1,900.00 $1,720.00
$1,900.00 $1,720.00
Vitals Monitor Features:
*Stand not included
Optional
Thermal printer, Wall Mount, EtCO2, Multigas, Nellcor/Masimo, IBP, Bar Code Scan
Wired or Wireless CMS (Central Monitoring System)
The Northern Aquarius plus is our most popular patient monitor bringing all major parameters to a convenient little monitor. Includes NIBP, SpO2, ECG, Surface Temp, PR and Touchscreen. Suitable for Adult, Pediatric and Neonate patients.
Featuring a suite of essential parameters and a user-friendly 8” colour TFT LCD touchscreen, the Northern Aquarius Plus is a reliable, economic choice for healthcare facilities seeking accuracy, portability, and ease of use.
Key Features:
Display
8” color TFT LCD Screen,relosution:800 x 600
ECG
Lead type
3-lead:l, II, Ill
S· lead:l, II, lll,aVR, a VI., aVF, V
Display sensitivity:
2.5mm;mv (x0.25), Smm;mv (x0.5), 10mm;mv (x1.0),
20mm;mv {x2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth
Diagnostic mode: 0.05Hz-100Hz
Monitor mode: 0.5Hz-40Hz
Surgery mode: 1Hz-20Hz
Strong filter mode: 5Hz-20Hz
CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance> SMO
Electrode polarization voltage range: ±400mV
Baseline recovery time<3s after defibrillation {in moni tor and
surgery mode)
Calibration signal:1mV (peak – peak), accuracy ±3%
RESP
Measurement method : Thoracic electrical bio1 pedance
Measuring lead: Lead I, II
Wave gain: x0.25, xO.S, x 1, x2
Respiratory impedance range: 0.5 ·50
Baseline impedance: 500-40000
Gain: 10 grades
Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s
TEMP
Measurement method: Thermistor
Measuring range: 5- SO’C (41-122’F)
Resolution: 0.1’C
Measurement accuracy: ±0.1’C
Printing (optional)
Built-in,Thermal dot array
Horizontal resolution :16 dots/mm (25 mm/s paper speed)
Vertical resolution:8 dots/mm
Paper speed:25 mm/s, 50 mm/s
Number of waveform channels:3
NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20-40s
Measurement type: Systolic, Diastolic,Mean
Measurement range {mmHg)
Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135
Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-100
Range of Mean pressure:
Measurement accuracy
Adult 20-230
Pediatric 20-165
Neonatal 20-110
Maximum average error: ±SmmHg
Maximum standard deviation: 8mmHg
Resolution: 1 mmHg
lnterval:1 ,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480minutes
Overpressure protection: Software and hardware,double
safety protection
Cuff pressure range: 0-280mmHg
Northern SpO2
Measurement range : 0·1 00%
Resolution: 1%
Accuracy: ±2% ( 70-100%, Adult/Ped iatric);
±3% { 70-100% , Neonate);
0 -69%,unspecified
Refreshing Rate: 1 s
Masimo SpO2 (optional)
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2% { 70-100% , Adult/Pediatric,non-motion,low prelusion);
±3% { 70-100%, Neonate,non-motion);
±3% ( 70-100% , motion);
0-69%,unspecified
Refreshing Rate: 1
Infrared Ear thermometer (optional)
Diplayed range: 34- 42.2’C {93.2-108 F’)
Operation ambient temperature range: 10-40’C{ 50-104’F)
Accuracy for displayed temerature range:
~35’C{ 95.9’F) -s42.2’C{ 107.6’F) range ±0.2’C{ 0.4’F)
< 35’C ( 95.9’F ) – ~34’C { 93.2’F) range ±0.3’C{ O.S’F)
Phasein IRMA Sidestream CO2 (optional)
Warm·up time: Full accuracy within 10 seconds
Sampling flow rate: SOml/min(+/·10/min)
Accuracy:±(0.2%+2% of the reading)
Measurement Range: 0 ·15%
Rise time: 200ms,typical at SOml/min flow rate
Total response time:
within 3 seconds(with 2m Momoline sampling line)
AWRR Range: 0·150bpm
AWRR Accuracy:±1 breath
Phasein IRMA Mainstream CO2 (optional)
Measurement Range: 0 ·15%
Warm-up time: Full accuracy within 10 seconds
Accuracy:±(0.2%+2% of the reading}
AWRR Range: 0-150bpm
AWRR Accuracy·+ 1 breath
Operating Environment
Phasein IRMA MAinstream CO2
Power: AC-=250, 50/60Hz
Temperature: 0-40C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate
How long will my delivery take?
Every order received by Rapid Medical Supplies before 5pm AEST will be dispatched on the same day. We're proud of our track record, which has seen 95% of deliveries to most metropolitan areas made in just 1-2 days. (Express service). Some bulk boxes and battery freight will be sent by road express, which will delay the shipping by 1-2 business days depending on your state & Territory.
Metropolitan Area
Brisbane, Gold Coast, Sydney, Melbourne, Perth*
Express: 1-2 Business Day
Standard/Premium: 2-5 Business Days
Adelaide
Express: 1-2 Business Day
Standard/Premium: 3-6 Business Days
Regional Area
Queensland, New South Wales, ACT, Victoria, South Australia
Express: 1-3 Business Days
Standard/Premium: 2-8 Business Days
Western Australia*
Express: 1-3 Business Days
Standard/Premium: 3-7 Business Days
Northern Territory
Express: 1-4 Business Days
Standard/Premium: 3-7 Business Days
Tasmania
Express: 1-3 Business Days
Standard/Premium: 3-8 Business Days
**The above days are only to be used as a guide, and not a guarantee.**
Please read full terms and conditions of delivery times here.
Please read full Shipping policy for delivery and dispatch here.
**Please note: Some bulky items will be shipped standard, not express shipping**
Shipping & Dispatch Notice
We aim to dispatch most orders within 1–2 business days. However, due to the specialised nature of some items—such as electric wheelchairs, oxygen machines, and high-value medical equipment—additional time may be required for thorough quality control (QC) checks prior to dispatch.
Some products may also be shipped from different warehouse locations (e.g. WA), which can affect transit times.
We appreciate your patience as we work to ensure your order arrives safely and meets our high quality standards.
Same day dispatch*
Order over $100
Free express shipping is currently being offered for orders over $100. This has exclusions such as bulky items, remote areas and post codes etc.
Order under $100
If you order is under $100, shipping costs will be calculated in the checkout section and options will be given for you to decide on your individual preferences such as cost, speed of delivery etc. In some circumstances, bulky items under $100 or remote locations under $100 will be subject to extra shipping charges after checkout. The customer service team will contact you at this time and provide options at your convenience.
**Please note: Some bulky items will be shipped standard, not express shipping**
For full terms and conditions, click this link to view full terms and conditions for shipping, rates and exclusions.
Are you a business and need an invoice before payment? Just fill out the form below and the team will send the invoice asap
Need an invoice for aged care or NDIS? Please provide all details below in the 'message' section and your contact details. We will send you an invoice within 1 business day.
This section is only relevant to products with Lithium batteries included. If you product above does not include a lithium battery, please ignore this section as it's universal across our website.
TRAVELING WITH A OXYGEN CONCENTRATOR
The FAA allows these device on board most U.S. aircrafts. If they have a FAA approval, they should allow the oxygen concentrator on board with the supply of the MSDS document. Rapid Medical Supplies can provide this upon request.
IMPORTANT: It is the responsibility of the patient to check with the specific airline carrier when traveling domestically and internationally.
Just because a oxygen concentrator is FAA approved, does not automatically mean a customer will be allowed to take the machine on the plane. It is up to the discretion of every flight, airline, airline pilot etc if the machines or batteries are allowed to be carried on board.
When traveling with the device, be sure to bring the AC Power Supply and the External Battery Charger (if you have
one) with you. It is advisable to use external power (i.e., plugged into a wall) whenever it is available to keep the
battery fully charged.
Bring enough charged batteries with you to power your concentrator for no less than 150% of the expected duration of your flight, ground time before and after the flight, security screenings, connections and a conservative
estimate for unanticipated delays. Note that per FAA regulations, all extra batteries are to be individually wrapped
and protected to prevent short circuits and carried in carry-on baggage onboard aircraft only.
The AC Power Supply cannot be used to charge the device battery when onboard aircraft. If traveling by bus, train
or boat, contact your carrier to find out about power port availability.
Email: hello@rapidmedicalsupplies.com.au
Phone: 1300 758 613
Trading name: Rapid Medical Supplies
Company Entity name: Magic Web Group Pty Ltd
ABN number: 65 830 387 563
Head Office Address: 3-9 Octal Street, Yatala, QLD, 4207
NDIS Number: 4050112091
NDIS Registration status: Active
NDIS support & Information: Call 1300 758 613
Link to NDIS website reference: https://www.ndiscommission.gov.au/provider-registration/rapid-medical-supplies